Specifications
2
Performing an update using rfw-update
29
Step 8: Rediscover the shelf
LogintotheATCA‐2210SCMthatishostingtheactiveShelfManager.AccesstheCLIand
enter:
platform‐mgmt
rediscoverShelf
ThisensuresthattheHPIRPTinfo rmationisinsyncwithnewversionsrunninginthesystem.
Recovering from update problems
Ifyouencounterproblemswithanupdate,youcanusuallyrecoverbyupdatingthe
componentfromtheredundantbank.Usersys‐updateorcomponentupdatetoolsfromthe
workingbank.
IfLinuxorU‐BootiscorruptedontheATCA‐1200,ATCA‐2210,ATCA‐7220orATCA‐9100,see
thePromentumSoftwareGuideforrecoveryinstructions.
IftheCPMBIOSiscorruptedinbothbanks,seetheCPMBIOSCrisisRecoveryInstructionsfor
thespecificCPM.
Note:Repeattheupdateprocessforredundantprogrammabledevicesinordertoflashthe
secondbank.ThissecondupdateisrequiredfortheCPMsbecausetheredundantBIOS
featurerequiresbothBIOSbankstobeatthesameversion.
Restoring older firmware or software
Todowngradetoapreviousversionoffirmwareorsoftware,seeChapter9,Installingprevious
firmwareorsoftwareversions,onpage 76.Refertothedocumentationfortheversionto
whichyouaredowngradingaswell.
SeetheproductrevisionlevelstableinthePromentumsoftwarereleasenotesforcomponent
versioncompatibility.Thesoftwarereleasenotesareavailableonthe latestPromentum
softwareproductmedia.