Specifications
2
Performing an update using rfw-update
25
Step 6: Update the AMC-7211 and AMC-7212
TheAMC‐7211andAMC‐7212areupdated asanon‐redundant componentaspartofthe
ATCA‐1200updatebundle,orfromaCPMhost.WhiletheAMCflashisanon‐redundant
component,thehostsupport,whichisupdatedatthesametime,isnotbecauseitresidesin
theredundantLMP.Consequently,thehostsupportisonlyupdatedintheactiveLMPandnot
intheredundantLMP.
WARNING!ThesupportfortheAMC‐7211andAMC‐7212mustbeinstalledandoperationalon
theCPMorATCA‐1200beforeyoucanupdatetheAMCs.Fordriverinstallationdetails,seethe
InstallingsoftwareonthecarriersectionintheInstallationProcedureSupplementchapterof
thePromentumQuadGigabitEthernetAMC
ReferencefortheAMC‐7211andAMC‐7212.
Update the LMP and AMC host support
FollowthesestepstoupdatetheLMPandAMChostsupportinbothAMCflashbanks.Inthis
procedure,bank0isthecurrentlyactivebankandbank1istheredundantbank.
1. Runrsys‐update‐‐redundanttoupdatebank1.Thesystemautomaticallyrebootstobank
1.
rsys‐update‐‐path/<tmp‐dir>/<update‐bundle>‐‐automatic‐‐redundant
Note:Seersys‐updatecommandoptionsonpage 32fordetailsaboutthersys‐update
commandoptionsusedinthisdocument.
2. ManuallyinstalltheCaviumhostsupportsoftware.TheCaviumprocessorsrebootafter
thehostsupportsoftwareisinstalled.Forinstallationinstructions,seetheUpdatingthe
softwaresectionintheQuadGigabitEthernetAMCReferenceforAMC‐7211andAMC‐
7212.
3. Runrsys‐update‐‐redundanttoupdatebank0.Thesystemautomaticallyrebootstobank
0.
rsys‐update‐‐path/<tmp‐dir>/<update‐bundle>‐‐automatic‐‐redundant
4. ManuallyinstalltheCaviumhostsupportsoftware.
5. Runrsys‐update
‐‐non‐redundanttoupdatetheAMC‐7211orAMC‐7212Caviumsagain.
Nowthenewactivebank(bank0)is updatedwiththenewCaviumhostsupport.
rsys‐update‐‐path/<tmp‐dir>/<update‐bundle>‐‐automatic‐‐non‐redundant
Update the IPMI firmware and FRU data
SeeChapter8,UpdatingIPMIFWandFRUdataforanAMCorRTM,onpage 72fordetails
aboutupdatingtheAMCIPMIfirmwareandFRUdata.