Specifications

2
Performing an update using rfw-update
25
Step 6: Update the AMC-7211 and AMC-7212
TheAMC7211andAMC7212areupdated asanonredundant componentaspartofthe
ATCA1200updatebundle,orfromaCPMhost.WhiletheAMCflashisanonredundant
component,thehostsupport,whichisupdatedatthesametime,isnotbecauseitresidesin
theredundantLMP.Consequently,thehostsupportisonlyupdatedintheactiveLMPandnot
intheredundantLMP.
WARNING!ThesupportfortheAMC7211andAMC7212mustbeinstalledandoperationalon
theCPMorATCA1200beforeyoucanupdatetheAMCs.Fordriverinstallationdetails,seethe
InstallingsoftwareonthecarriersectionintheInstallationProcedureSupplementchapterof
thePromentumQuadGigabitEthernetAMC
ReferencefortheAMC7211andAMC7212.
Update the LMP and AMC host support
FollowthesestepstoupdatetheLMPandAMChostsupportinbothAMCflashbanks.Inthis
procedure,bank0isthecurrentlyactivebankandbank1istheredundantbank.
1. Runrsysupdate‐‐redundanttoupdatebank1.Thesystemautomaticallyrebootstobank
1.
rsysupdate‐‐path/<tmpdir>/<updatebundle>‐‐automatic‐‐redundant
Note:Seersysupdatecommandoptionsonpage 32fordetailsaboutthersysupdate
commandoptionsusedinthisdocument.
2. ManuallyinstalltheCaviumhostsupportsoftware.TheCaviumprocessorsrebootafter
thehostsupportsoftwareisinstalled.Forinstallationinstructions,seetheUpdatingthe
softwaresectionintheQuadGigabitEthernetAMCReferenceforAMC7211andAMC
7212.
3. Runrsysupdate‐‐redundanttoupdatebank0.Thesystemautomaticallyrebootstobank
0.
rsysupdate‐‐path/<tmpdir>/<updatebundle>‐‐automatic‐‐redundant
4. ManuallyinstalltheCaviumhostsupportsoftware.
5. Runrsysupdate
‐‐nonredundanttoupdatetheAMC7211orAMC7212Caviumsagain.
Nowthenewactivebank(bank0)is updatedwiththenewCaviumhostsupport.
rsysupdate‐‐path/<tmpdir>/<updatebundle>‐‐automatic‐‐nonredundant
Update the IPMI firmware and FRU data
SeeChapter8,UpdatingIPMIFWandFRUdataforanAMCorRTM,onpage 72fordetails
aboutupdatingtheAMCIPMIfirmwareandFRUdata.