Specifications

2
Performing an update using rfw-update
20
Step 4: Update IPMC FPGA devices
IPMCFPGAdevicesformodulesmustbeupdatedseparatelyusingrsysupdatebeforerunning
rfwupdatetoautomaticallyupdatetheothermoduledevices.Refertotheproductrelease
notestoidentifyanyIPMCFPGAupdates.
Followthesestepstoperformtheupdate:
1. DeterminewhichmodulesrequireIPMCFPGAupdatesbycomparingtheirinstalledIPMC
FPGAversionwiththelatestPromentumsoftwarerelease.SeeDeterminewhichmodules
requireanIPMCFPGAupdateonpage 17fordetails.
2. RunrsysupdateoneachmodulethatrequiresanIPMCFPGAupdate,specifyingthepath
tothefirmwareupdatebundle.Thefollowingcommandupdatesthemodule’sIPMCFPGA
andassociatedIPMIfirmware:
rsysupdate‐‐path<xxxfirmware.tgz>‐‐ipmifirmware:update
Note:Seersysupdatecommandoptionsonpage 32fordetailsaboutthersysupdate
commandoptionsusedinthisdocument.
ToupdatetheIPMCFPGAfortheATCA5010orATCA5014SPM,runthefollowing
commandfromtheATCA2210andspecifytheIPMBtargetaddress(0xE4fortheSPMin
slot7,or0xE6fortheSPMinslot8):
rsysupdate‐‐path<xxxfirmware.tgz>‐‐ipmifirmware:update‐ipmbtarget
<IPMBtargetaddress>
3. Activatetheupdatedcomponent:
rsysupdate‐‐path<xxxfirmware.tgz>‐‐ipmifirmware:activate
Similarly,activatetheupdatedcomponentfortheATCA5010orATCA5014SPM:
rsysupdate‐‐path<xxxfirmware.tgz>‐‐ipmifirmware:activate‐‐ipmbtarget
<IPMBtargetaddress>
4. Removeandreinsertthemodule.
Note:Ifthemodulepowercyclesthenitdoesnotneedtoberemoved.Somemodules
withrelease3.5.0orgreaterPromentumsoftwarewillpowercycleautomatically,so
removalandreinsertionisnotrequired.
SeeAppendixC,PowercyclingafterIPMCFPGAupgrades,onpage 88fordetailsaboutthe
modulesthatmayrequireamanualpowercycle.
SeeChapter3,Usingrsysupdateforsingleproductupdates,onpage 31foradditional
informationaboutusingrsysupdateforindividualupdates.