Specifications
7
General troubleshooting tips
89
General troubleshooting tips
WhentheCPMdoesnotperformasexpected,lookforsymptomsthatmightclarifythe
cause.Performingthefollowingactionscanhelpdiagnosetheproblem:
•CheckthestateoftheLEDsontheCPMandothermodulesintheplatform,especially
thepowerandoutofserviceLEDs.
•ChecktheeventsloggedintheShelfManager’ssystemeventlog(SEL)ortheCPM’s
localSEL.ForinformationonaccessingtheSEL,seeAccessingtheSELonpage 78.
•ChecktemperaturesontheCPM.IftheRadiSysShelfManagerisused,seethe
troubleshootinginformationintheShelfManagementSoftwareReferencefordetails
on
howtoperformthesequeries.
•VerifytheIPaddressandthesubnetmaskassignment.SeetheSoftwareGuidefor
ManagementProcessorsandGeneralPurposeComputingProcessorsfordetailson
verifyingthesea ssignments.
Symptoms and recommended actions
Thistablelistspossibletroubleshooting scenarios.Lookthroughthelistedsymptomsto
seeifanyapplytoyoursituationandfollowtherecommendedactionsfortheapplicable
symptoms.Whenanactionrevealsthecauseoftheproblem,resolvetheproblemas
indicated.
Table 25. Troubleshooting actions based on symptoms
Symptom Recommendation
The power LED on the CPM is not lit. • Make sure the CPM is completely inserted and the hot swap latch is engaged.
• Verify that other modules in the shelf are powered. If not, check the power to the shelf.
• Inspect the rear connectors for damage. If they show no sign of damage, try the following:
• carefully insert the CPM into a different slot
• carefully insert a different CPM in the original slot
WARNING! Do not force the insertion of the CPM. If insertion is not easy, the pins
on the backplane connector may be damaged, which could potentially damage the
rear connectors on the CPM.
• Verify the CPM is in the M4 hot swap state (active state). (See the Shelf Management Software
Reference for more information on hot swap states.)
• Check to see if the software installed on the CPM is communicating with the platform’s Shelf
Manager or whether the CPM is waiting for an external Shelf Manager to enable it.