Specifications
6
System BIOS
78
Accessing the SEL
MessagesintheSELareview edusingthersys‐ipmitoolutility.Forexample,toviewthe
systemSELfromasystemthathasLANconnectivitytotheactiveShelfManager:
rsys‐ipmitool‐Ilan‐H<Shelf_Mgr_IP_addr>‐ANONE‐t0x20sellist
Usethe‐hoptiontoobtainhelpusingtheutility.ToviewtheCPM’slocalSEL,substitute
theIPMBaddressoftheCPMforthevalue0x20inthecommandabove.SeetheShelf
ManagementSoftwareReferencefortheIPMBaddressesoftheslotsineachRadiSys
shelf.
SEL event codes
Table 23liststhesensoreventsgeneratedbytheBIOS.
Table 23. SEL sensor events generated by the BIOS (sheet 1 of 7)
Sensor type
Sensor type
code
Sensor-specific
offset
Event description
Memory 0Ch 00h Correctable ECC / other correctable memory error
See event offset 00h in Memory on page 119.
01h Uncorrectable ECC / other uncorrectable memory error
See event offset 01h in Memory on page 119.
02h Parity
03h Memory scrub failed (stuck bit)
04h Memory device disabled
05h Correctable ECC / other correctable memory error
logging limit reached