Specifications

C
Connector Pinouts and Jumper Settings
150
119 GND Logic Ground
120
MB_RX13– AMC Update channel RX from AMC to Slow Path Buffer
121
MB_RX13+ AMC Update channel RX from AMC to Slow Path Buffer
122
GND Logic Ground
123 MB_TX14 Carrier Not Used
124 MB_TX14+ Carrier Not Used
125
GND Logic Ground
126 MB_RX14– AMC Not Used
127 MB_RX14+ AMC Not Used
128
GND Logic Ground
129
MB_TX15– AMC I
2
C clock from AMC through CPM to RTM
used for SFP and LED control
130
MB_TX15+ AMC
Carrier
I
2
C data from AMC through CM7 to RTM
used for SFP and LED control
131
GND Logic Ground
132
MB_RX15– RTM Serial port RX from RTM through CPM to AMC
used for AMC debug
133
MB_RX15+ AMC Serial port TX from AMC through CPM to RTM
used for AMC debug
134
GND Logic Ground
135
MB_TCLKC– Carrier Not supported
136
MB_TCLKC+ Carrier Not supported
137
GND Logic Ground
138
MB_TCLKD– AMC Telecom Clock D–
139
MB_TCLKD+ AMC Telecom Clock D+
140
GND Logic Ground
141
MB_TX17– Carrier SERDES TX from RTM through CPM to AMC
142
MB_TX17+ Carrier SERDES TX from RTM through CPM to AMC
143
GND Logic Ground
144
MB_RX17– AMC SERDES RX from AMC through CPM to RTM
145
MB_RX17+ AMC SERDES RX from AMC through CPM to RTM
146
GND Logic Ground
147
MB_TX18– Carrier SERDES TX from RTM through CPM to AMC
148
MB_TX18+ Carrier SERDES TX from RTM through CPM to AMC
149
GND Logic Ground
150
MB_RX18– AMC SERDES RX from AMC through CPM to RTM
151
MB_RX18+ AMC SERDES RX from AMC through CPM to RTM
152
GND Logic Ground
153
MB_TX19– Carrier SERDES TX from RTM through CPM to AMC
154
MB_TX19+ Carrier SERDES TX from RTM through CPM to AMC
155
GND Logic Ground
156
MB_RX19– AMC SERDES RX from AMC through CPM to RTM
Table 47. AMC connector pinout (continued)