Specifications

111
B
List of sensors
+12V 19h Voltage 02h
Threshold
01h 12.00 R, T - - [u,l][nr,c,nc]
As &
De Analog A - 0.2 01h
This sensor measures voltage in volts.
Default thresholds
LNR LC LNC UNC UC UNR
0.00 10.84 11.42 12.60 13.19 13.78
+5V 1Ah Voltage 02h
Threshold
01h
5.00 R, T - - [u,l][nr,c,nc]
As &
De
Analog A - 0.2 01h
This sensor measures voltage in Volts.
Hysteresis: ±0.10
Default thresholds
LNR LC LNC UNC UC UNR
0.00 4.52 4.76 5.25 5.50 5.74
+5V
Standby 1Bh Voltage 02h
Threshold
01h 5.00 R, T - - [u,l][nr,c,nc]
As &
De Analog A - 0.2 01h
This sensor measures voltage in volts.
Hysteresis: ±0.10
Default thresholds
LNR LC LNC UNC UC UNR
0.00 4.51 4.75 5.25 5.50 5.74
+3.3V
IPMI
1Ch Voltage 02h
Threshold
01h
3.30 R, T - - [u,l][nr,c,nc]
As &
De
Analog A - 0.2 01h
This sensor measures voltage in Volts.
Hysteresis: ±0.10
Default thresholds
LNR LC LNC UNC UC UNR
0.00 2.98 3.15 3.47 3.64 3.78
+3.3V 1Dh Voltage 02h
Threshold
01h 3.30 R, T - - [u,l][nr,c,nc]
As &
De Analog A - 0.2 01h
This sensor measures voltage in volts.
Default thresholds
LNR LC LNC UNC UC UNR
0.00 2.98 3.15 3.47 3.64 3.78
+1.8V 1Eh Voltage 02h
Threshold
01h
1.80 R, T - - [u,l][nr,c,nc]
As &
De
Analog A - 0.2 01h
This sensor measures voltage in Volts.
Default thresholds
LNR LC LNC UNC UC UNR
0.00 1.61 1.71 1.90 1.98 2.08
Table 35. Managed sensors (continued)
Sensor
name
Sensor
number
Sensor
type
Event/
reading
type
Normal reading
Event
offset
ED1
[3:0]
Event data
Event
Assert/Deassert
events
Readable
value/offsets
Rearm
Standby
Polling time
(seconds)
SDR type
NotesByte 2 Byte 3