Specifications

B
IPMI Commands and Managed Sensors
100
OEM command descriptions
Special commands are available to facilitate CPM-specific functionality. Descriptions of each
command and their parameters are listed in this section.
Restore Factory Defaults
Restores the factory default configuration and threshold parameters for onboard sensors. No data
byte is required.
Disable CFD
Indicates to the IPMC that the CFD watchdog timer needs to be disabled. No data byte is required..
Set WDT Reset Type
Allows a BMC watchdog timeout configured for "Hard Reset" to cause a cold reset..
Get Control State (for debug only)
Returns the current state of a control pin Use only for debug situations..
NetFn 0x30
Cmd 0x05
Data field Byte N/A N/A
Response field Byte 1 Completion code
NetFn 0x30
Cmd 0xE7
Data field Byte N/A N/A
Response field Byte 1 Completion code
NetFn 0x30
Cmd 0xA8
Data field Byte 1 Reset Type Configuration: 0: Cold Reset
Response field Byte 1 Completion code
NetFn 0x30
Cmd 0x21
Data field Byte 1 FRU ID
Byte 2 Control number
Response field Byte 1 Completion code
Byte 2 Control state: 0x00 = de-assert; 0x01 = assert