Specifications

C
Updating IPMI FW and FRU Data for an AMC or RTM
59
Reverting to backup firmware
Usethisprocedureonlyifyouneedtoreverttothebackupfirmwareversionstoredonthe
MMC.Afterperformingtheprocedure,youwillnotbeabletorunthenewversionag ainuntil
afullupgradeiscompleted.
Enterthiscommand:
rsysipmitool‐Ilan‐H<shelfIPaddress>‐Anone‐T<carrierIPMBaddress>
B0‐t<AMCorRTMIPMBLaddress>‐b7hpmrollback
An0xD5errorcodemaybereturnedifthereisnorollbackversion.
Updating AMC or RTM FRU data
Usethe rmcptautilitytoupdatetheAMCortheRTMFRUdata.Enterhelponthermcpta
commandlineforalistofavailablecommands.
UpdatetheAMCorRTMFRUdatabyenteringthefollowingcommands:
1. rmcpta‐h<shelfIPaddress>
2. targetfwd<carrierIPMBaddress><AMCorRTMIPMBLaddress>
3. updatefru<FRUupdatefile>backup.bin
TheupdatefrucommandsavesthecurrentFRUdatatothebackup.binfile,andthen
proceedstoupdatethedeviceFRUdata.Thebackup.binfilecanbeusedtorecoverFRU
dataifnecessary.
WhenupdatingtheFRUdata,thermcptautilitymaypromptforinputtoresolve
differencesinformatbetweentheoldandthenewdata.Theutilitymayalsowarnifthe
updatefiledoesnotmatchthetargeteddevicetopreventthedevicefrombeingupdated
withincorrectdata.Youcanusethe‐‐autooptiontoavoidsuchprompts.
Sample FRU data update
rmcpta‐h10.2.113.200
targetfwd0x820x7A
updatefruAMC72xxFRUv0101.frubackup.bin
parsefru0
Note:Thefinalparsefru0commandverifiestheFRUinformation.