IfaparticularFRUismissingfromtheversionreport,thenitsBladeHSDisnotregisteredwith
theShelfManagerandyouwillneedtoedititsconfigurationfileandsetupIPinterfaces.See
ConfigureanIPinterfacefortheBladeHSDbelowforinformation.
Configure an IP interface for the Blade HSD
YoumustconfigureanIPinterfacefortheBladeHSDwhenperformingthefollowingtypesof
updates:
Updatingmodulesonathirdpartyshelf(i.e.,nonRadisysshelf)
UpdatingaCPM
TheBladeHSDconfigurationfile“rsyshsd.confislocatedoneachmoduleatthislocation:
/etc/rsyshsd.conf
ThedifferentRadisysmoduletypeshaveuniquersyshsd.conffiles.However,thefiledoshare
threecommonparametersforconfiguringtheIPinterface:
RSYSHSD_BASE_INTERFACE:Thisparameternamesaninterfaceonthemodulethatthe
BladeHSDusestoattachaRMCPinterface.ThisenablesRMCPbaseremoteHPIaccessto
theBladeHSDovertheinterface.Theadvantageofprovidinganinterfacenamerather
thananIPaddressisthatitenablesBladeHSDtosupportdynamicallyallocated addresses
andsituationswheretheIPaddresschangesduringoperation.BladeHSDtrackstothe
interface(e.g.,eth0)andisabletodetectanyipaddresschangesandautomaticallyre
bindtothatinterfacewithitsupdatedipaddress.
RadisysrecommendsusingaportassociatedwiththeBaseEthernetorabondedinterface
forthisparameter.
RSYSHSD_FABRIC_INTERFACE:Thisparameternamesanadditionalinterfaceonthe
modulethattheBladeHSDusestoattachasecondRMCPinterface.Astheparameter
nameindicates,RadisysrecommendsusingaportassociatedwiththeFabricEthernetfor
thisinterface.However,thisisnotarequirement,andanonfabricinterfacecanalsobe
usedforthisparameter.
Forthirdpartyshelfupgrades,orupgradesdirectedatindividualmodulesratherthan
throughtheShelfManager,thisparametercanbeconfiguredwithaninterfacereachable
fromtheupdatehost.Forexample,themanagementporteth0ortheBaseEthernet
interfaceeth1onLMPbasedmodules.
RSYSHSD_SHMS_INTERF ACE:Thisparameterspecifieswhethertheinterfacenamedfor
theRSYSHSD_BASE_INTERFACEparameterortheinte rfacenamed
forthe
RSYSHSD_FABRIC_INTERFACEparameteristhepreferredinterfacefortheBladeHSDto
communicatewiththeShelfManager.TheIPaddressofthechoseninterfaceis
communicatedwiththeShelfManager,andthenusedinestablishing HPIcommunication
withtheBladeHSD.Radisysrecommendsusingthesameinterfaceasthe
interfacenamed