Specifications
2
Performing Updates Using rsys_swm
14
Determine when to perform the update
Yourplanningshouldtak eintoaccountthetimeneededtoperformtheupdateandthe
downtimeinvolved.Table 3showstheestimatedtimeittakesforoneupdatepassona
fully‐populatedplatform.
Usingthisestimate,asingleupdatepasswilltak eapproximately16minutes.
Theactualtimeittakesonyoursystemtoperformanupdatepasswillvarydependingonthe
numberofphasesdefinedintheconfigurationfile,networkingspeed,IPMBtraffic,andJFFS
accessspeed.Thefirmwareandthesoftwareupdatesaredoneonlivesystems,sodowntime
islimitedtorebootsthattakeapproximately5minutesforallmodulesintheshelf.
Takeintoconsiderationthatyouwillneedtoperformmorethanoneupdatepasstoupgrade
afully‐populatedplatform.Forexample,ifyouareperformingasinglebankupgrade,youwill
needtoperformtwoupdatepasses.Ifyouareupgradingbothbanks,youwillneedto
performfourupdatepasses(seepage 13forexamplesoftheupgradeprocedures).Youwill
alsoneedtofactorinanytimeittakestoperformtheswitchoverandtheverificationsteps
betweentheupdatepassesforyourtotalupgr adetime.
Save the running configurations on modules
Verifyallthemodulesareinastablestateandsavetheirrunningconfigurations.
TheSMFpreser vesdefaultconfigurationsacrossupdatesfortheATCA‐1200,ATCA‐2210,
ATCA‐7220,andATCA‐9100.Configurationsarepreservedinbothbankstoretaintheexisting
setupinformation.EachATCAsoftwarereleaseCD‐ROMimagecontainsalistoffilestobe
preserved,andyoucangenerateacustomlistthatspecifiesadditionalfileswithinthe/etc
directorytopreserve.
Filepreservationworksasfollows:
•BeforetheOSupdatebegins,theconfigurationiscopiedfromtheactiveflashbanktothe
standbyflashbank.
•Aftertheupdate
isactivated,themodulerebootstothestandbybank.
Duringbootup:
•thesavedconfigurationissavedtoatemporarylocation,
Table 3. Estimated time per update pass
Tasks completed during update pass Time Affected components
Bundle download and image verification 3 minutes All modules, including Blade HSD restart for bundle
activation.
Installation and verification pass 11 minutes All LMP, IPMC, BIOS components.
The components are updated in parallel. The process
completes when everything has finished updating on all the
components.
Activation 2 minutes All the Blade HSDs.