Specifications

5
Managing Alarms and Events
93
Figure 9. Format of alarm messages on the SDP
Set to the location of the resource that has the alarm.
The format is NNM for front modules, where NN is the
slot number and M is the Managed FRU Id, which is set
to 0 when alarm refers to the front module.
For all other resources, the format is TNN, where NN is
the slot or instance number and T is one of the following
letters indicating the type of resource:
P - Power Entry Module
F - Fan Tray
S - SPM
U - User alarm
M - Shelf Manager
C - Chassis
A - Alarm Manager
Severity codes:
CRT - Critical
MAJ - Major
MIN - Minor
Text description of the alarm.
Display * if system alarm is unacknowledged, otherwise leave blank.
Set to the AlarmId of the entry in the DAT.
Alarm ID Severity
1
910
Location
14
Alarm Description
18 40