UpperMajortemperatureeventsma yindicatethattheambienttemperatureistoohigh,in
whichca seyoumightneedtolowertheambienttemperature.Theymayalsoindicatethatair
flowintotheshelfhasbecomerestricted,inwhichcaseyouneedtoinvestigatethecause.
Remove,clean,andreinsert
thefanfilterifithasbecomeclogged.
UpperMinorandUpperMajortemperatureeventassertionscausethefanspeedstoincrease
inincrementsuntiltheconditioniscleared.Adeassertioneventfromthesamesensor
indicatesthattheconditioniscleared,andthefanspeedisdecreasedaccordingly.Apattern
oftemperatureeventassertionsanddeassertionsmayleadtoanincreaseintheminimum
fanspeed.Formoreinformation,seeAdaptivefanflooralgorithmonpage 34.
WhentheShelfManagerreceivesanUpperCriticaltemperatureevent,itattemptstopower
offthemoduleassociatedwiththesensor.Evenwhilepoweredoff,thesensorsarestill
functional.Thealarmconditionmaynotbeclearedimmediately,ifatall,sothefansmay
continuetorunatahighspeed.
IPMB and communication alarms
TheIPMBandcommunicationalarmsindicateanabnormalconditionforanIPMCIPMB
interfaceorforcommunicationsbetweentheShelfManagerandagivenFRU.
FRUcommunicationlostalarmsaregeneratedbytheresourceinsteadofbyasensor.IPMB
alarmsaregeneratedbyOEMsensors.AnOEMsensorhasan8bitvalueandisdefinedbyan
OEM.OEMsensorsareasubsetofthediscretesensortype,whichcanhaveupto16bit
mappedstates.
Shelf Manager status alarms
TheShelfManagerstatusalarmsindicatethattheShelfManagerisnotfunctioningnormally
orinfullhighavailability(HA)mode.
ShelfManagerstatusalarmsaregeneratedbyOEMsensors.AnOEMsensorhasan8bit
valueandisdefinedbyanOEM.OEMsensorsareasubsetofthediscretesensortype,which
canhaveupto16bitmappedstates.
FRU aggregate status alarms
TheFRUaggregat estatusalarmsindicatethataFRUhassignificanterrorconditions.These
couldinclude:
•OperationalerrorconditionssuchasIPMCselftestfailureorEKeyingerrors.
•Powerstatuserrorsbasedonthreshold crossings.
Note:AnadditionaltemperatureaggregatesensorexistsonallFRUresources.Thoughthis
sensordoesnotgenerateseparatealarmsandevents,youcanreaditforanoverallviewof
theboard’sthermalstatus.ThermalconditionsofaFRUwillgeneratealarmsfromassociated
temperaturesensors.
FordetailsonthepossiblestatesoftheFRUaggregatestatussensors,seeTable 19on