Specifications

4
Changing Shelf Settings Using HPI
70
FRU power-on sequence commit status sensor
TheshelfresourcecontainsanadditionalsensorcalledtheFRUpoweron sequencecommit
statussensor(0x1300).Thissensorindicateswhethertheconfiguredpoweronsequencehas
beencommitted.ThissensorisanOEMsensorsupportingonlyeventstates.Nonumeric
readingsorthresholdsaresupported.ThefollowingaretheHPIsensorspecificeventstates
supportedbythissensor:
Error conditions
Whendoingacommitusingthecommitcontrol,ifduplicateResourceIdsarefoundinanyof
the22Power On Sequencecontrols,theerrorcodeSA_ERR_HPI_DUPLICATEisreturned.
WhilesettingthecontrolstateofanyPower On Sequencecontrol,iftheResourceIdisnot
foundtobeavalidslotresourcesID,theerrorcodeSA_ERR_HPI_INVALID_DATAisreturned.
0x0001(SAHPI_ES_STATE_00) StatusreportedbytheFRUpoweron sequencecontrols
isthepresentstatusintheshelfactivationandpower
managementrecord(thatis,thepoweronsequencein
theshelfactivationandpowermanagementrecordisup
todate).
0x0002(SAHPI_ES_STATE_01) OneormoreoftheFRUpoweron sequencecontrols
havebeenmodifiedbutnotyetcommittedtotheshelf
FRUinformation.YoumustusetheFRUpoweron
sequencecommitcontrol(control0x1300)towritethe
updatedpoweronsequencetotheshelfFRU
information.