Specifications
C
IPMI Commands and Managed Sensors
145
30 Get Address Info failed
31 Self Test Error
32 Self Test Check failed
33 Set IPMB-<A|B> State <Enable|Disable>
34 Comm Loss (M7)
35 <System Interface> Status
36 Ignoring SDR <sdr> with invalid owner <name/id>
37 Can't read DLR
38 Can't read SDR<record id>
39 Could not get DPT info
40 Could not reserve DPT
41 Could not get DPT entry<entry id>
42 Stable Redundancy Role
43 Local HA State Event Lost
44 Peer HA State Event Lost
45 Cannot ping local ShMC
257
(0x101)
FRU Power
Status
Power Unit Threshold 0x1 State 0x1: Lower minor.
State 0x2: Lower major.
State 0x4: Lower critical.
State 0x8: Upper minor.
State 0x10: Upper major.
State 0x20: Upper critical.
Possible readings are encoded as a bit mask of 64 values:
0 No power information record, cannot activate
1 Get Power Level failed, assuming worst case
2 No Shelf FRU power descriptor found
3 No Shelf FRU power feeds attached
4 Get Power Level (Level Type) failed
5 Number of early/desired levels don't match
6 Number of desired levels is zero
7 Power level zero desired
8 Early draw is less than steady draw
9 Set Power Level failed
Table 19. Managed sensors for each FRU (continued)
# Name Type Category
Normal reading
or event state
Explanation of values