Specifications
C
IPMI Commands and Managed Sensors
144
Table 19. Managed sensors for each FRU
# Name Type Category
Normal reading
or event state
Explanation of values
256
(0x100)
FRU Operational
Status
Operational Device
enabled
0x1 State 0x1: FRU is operational without faults.
State 0x2: FRU operation is degraded or disabled.
Possible readings are encoded as a bit mask of 64 values:
Index Meaning
0 Bused Resource Release
1 Query for bused resource
2 Cooling Power Off
3 Cooling Power On
4 Shutdown Fan
5 Get Fan Speed Properties
6 Get Fan Level (Critical severity)
7 Get Fan Level (Major severity)
8 Set Fan Level (Critical severity)
9 Set Fan Level (Major severity)
10 Fan Critical Alarm
11 Self FRU Critical Alarm
12 Minor Temp Alarm
13 Major Temp Alarm
14 Critical Temp Alarm/No Temp Alarms
15 E-Key load failed
16 E-Key enable error on <interface><channel>
17 Get Port State failed<channel>
18 IPMB <A|B> State
19 Waiting for system manager to activate
20 IPM not in M4 or M5, cannot activate
21 <Activation>|<Deactivation> Error
22 Peer LAN sync channel not defined
23 Local sync channel not started
24 Cannot calculate peer IP address
25 Peer LAN channel has unknown properties
26 Peer LAN session error, closing
27 Peer LAN connect error
28 Sync thread exited
29 Cannot ping peer ShMC