Specifications

6
Troubleshooting
131
Resolving shelf FRU information issues
ThissectionprovidesinformationonresolvingshelfFRUinformationproblems,includinghow
tosaveandrestoreshelfFRUinformationusingthersysipmitoolutility,whichisinstalled on
theShelfManagermodule.Theopensourceipmitoolutilitycanalsobeused.AlistofIPMB
addressesisincluded.
Actions to avoid
ShelfFRUinformationrecordscangetcorruptedwhen:
•InterruptionsoccurwhenwritingtotheshelfFRUdevice.Interruptionsmightoccurifthe
ShelfManagerisstoppedortheSCMpowerisremovedwhilewritingarecord.Theycan
alsooccuriftheremotehostfromwhichyouareupdatingtheshelfFRUdatausing
ipmitoolisshutdownorlosesitsconnectiontotheSCM.
•AnapplicationwritesdirectlytotheshelfFRUdevicewithinvaliddata.
•BothSCMsareswappedoutatthesametimeinanATCA6006shelfwhentheSCMs’
persistentcopyfilesaredifferentanddonotmatchtheshelfFRUdevice.Swappingouta
singleSCMdoesnotcauseaproblem.
Understanding what has occurred
IftheactiveShelfManagercannotaccesstheshelfFRUdevice,theShelfManagertriesto
verifyitsowninformationbygettinginformationfromstandbyShelfManager.TheShelf
ManagerwillnotstartupwithonlyitsowncopyoftheshelfFRUinformationunlessthereis
onlyoneSCMintheshelf. InsteadtheSCMwillgointodebugmode.
ErrorsarewrittentotheShelfManagerlogswhenthedataintheshelfFRUdevicecannotbe
readoroverwritten.
A user alarm cannot be created.
Error code:
SA_ERR_HPI_OUT_OF_SPACE
The DAT has reached the limit (50 by default) for the number of user alarms that can be active simultaneously.
Consider these options:
Delete the oldest user alarm from the DAT
Delete the most minor user alarm from the DAT
Choose not to add the new user alarm
For information about configuring the number of user alarms, see Configuring HPI alarms on page 46.
Data cannot be added to the
MultiRecord area.
Error code:
SA_ERR_HPI_OUT_OF_SPACE
Neither new records nor new data for the existing PICMG MultiRecord area can be added directly to the FRU
data inventory for a module or a shelf. The OEM MultiRecord area can be updated directly. Instead, use one of
these two methods to update the MultiRecord area:
Setting controls in the shelf resource
Using a utility such as rsys-ipmitool to overwrite the existing image
Table 15. Symptom/response for Shelf Manager problems (continued)
Symptom Response