Specifications

6
Troubleshooting
122
Make sure the Shelf Manager software is running
MakesuretheShelfManagersoftwareisrunning.TheActiveLEDoftheSCM(oroneSCMofa
redundantpair)shouldbeamberandtheOOS(OutofService)LEDshouldbeoff.Fora
modulerunningtheShelfManagerinanACTA6002shelf,thePWRLEDshouldbegreen.In
thisshelf,theOOSLEDisnotupdatedbytheShelfManager.
Additionally,theLinuxcommandshmgrstatusshouldshowastatusof“started. ”Theshmgr
role
commandshouldshow“activeor“standby .
•Ifthestatusisstopped,ensurethattheSCMisinoneofthetwohubslots.Thehubslots
are7and8intheATCA6000andATCA6014shelves,1and2intheATCA6006shelf,and
8and9intheATCA6016shelf.
•FortheATCA6002shelf,ifthestatusisstopped,ensurethatthemodulerunningthe
ShelfManagerisinnodeslot1.
•Ifthestatusisstopped,shelfmanagementfunctionalitymayhavebeendisabled
intentionallytoletitoperateinanonRadisysshelf.Ifitwasdisabledintentionally,seethe
SwitchandControlModuleInstallationGuideforinstructionsonreenablingit.Ifitwas
notintentionallydisabled,usetheLinuxcommandshmgrstarttostartit.
•Iftheroleis“unknown,ShelfManagercommunicationwiththelocalIPMCisnot
working.
a. RestarttheShelfManagerandchecktheroleoftheShelfManagermodulewiththe
shmgrrolecommandagain.
b. ReboottheShelfManagermoduleandchecktheroleagain.
WhentheshelfhasredundantSCMs,alsomakesuretheShelfManagerisrunningonthe
otherSCM.
Check for IPMI serial device errors
CheckforIPMIserialdevicedrivererrorsasfollows:
1. FromtheSCM’sLinuxprompt,issuethecommand:
cat/proc/driver/ipmi
2. Verifythatthe“Rxerrorcountersattheendofthelistareeitherzeroorarenot
incrementingatregularintervals.Steadilyincreasingerrorcountsheremayindicatea
hardwaredefect.