Specifications
6
Troubleshooting
118
3. IftheFRUisfoundtobeinM2andAutoInsertiontimerisnot‐1oralargevalue,checkthe
stateofthe'FRUActivationControl'0x1020ontheSlotResourceassociatedwiththeFRU.
ForexampleiftheFRUisinslot2ina14slotshelf
withResourceId0x20096thenitsslot
Resourcewillbe0x2FF96.YoucandeterminetheslotresourcefromaResource'sentity
path.TheFRUResource'sEntityPathwillbeasupersetofitsassociatedSlotResource's
entitypath.Forexample,fortheslot2boardexampleabove:
SlotResource0x2ff96entitypath‐
/ADVANCEDTCA_CHASSIS_00/PHYSICAL_SLOT_02
FRUResource0x20096entitypath‐
/ADVANCEDTCA_CHASSIS_00/PHYSICAL_SLOT_02/PICMG_FRONT_BLADE_02
Ifthe'FRUActivationControl'reportsaMANUALmode,itmeansthatslotisconfiguredto
alwaysbemanuallyactivated.Asaconsequence,theShelfManagerwillnotactivatethe
FRU,butinsteadleaveitinanINSERTION_PENDINGstate.Thesystemmanagerneedsto
manuallyactivatetheFRUinthiscase
usingtheHPIhotswapAPI.
TorestoreautomaticShMS‐controlledactivationsetthemodeofthe'FRUActivation
Control'toAUTOmode.
4. IftheFRUisinM3,checktoseeiftheShelfManagerhasgranteditpower.Thiscanbe
checkedviathe'AssignedPowerSensor',Sensor0x1011,ontheSlotResourceassociated
withtheFRU.ThemechanismforidentifyingtheSlotResourcewasexplainedunder
Step 3above.
Anon‐zeroreadingreportedbythe'AssignedPowerSensor'indicatesthattheShMShas
grantedpowersuccessfullytotheFRU.NowitistheIPMC'sresponsibilitytotransitionthe
FRUtoM4.IftheFRUisaRadisysboard,contactRadisysTechnicalSupportforfurther
investigation.
5. IftheFRUisinM3anddoesnothavepayloadpowergrantedtoit,theFRUmightbe
askingformorepowerthantheShMScangranttothatslot.Performthefollowingsteps:
a. CheckthemaximumpowerallowabletothatFRU'sslotbyreadingthe'MaxPower
CapabilitySensor',sensor0x1012,ontheFRU'sSlotResource.Checkhowmuch
powertheFRUisrequestingbyreadingthe'DesiredPower‐intenthsofWatts'
control,0x1030,ontheFRU'sResource.IftheFRU'srequestedpowerismorethanthe
maximumpowertheShMScanallowtothatslot,thatFRUcannotbeactivatedinthat
slot.
b. IfthisFRUisamanagedFRU(e.g.AMC),itsre questedpower,theparentFRU'spower,
andanyothermanagedFRUalreadyactivatedonthatparentFRUispossibly
exceedingthe
maximumpowercapabilityoftheparentFRU'sslot.
Forexample,aslotmightallowaMaximumof200W.ItalreadyhasanAMCCarrier
andanRTMwithpowerof120W(includingmanagementpower)and30W
respectively.Inthiscase150Wisalreadygrantedfromthatslot'smaximumbudget.
Nowif
anAMCisinstalled ontheAMCcarrierwithitsownrequirementof60Wthen
thetotalpowerbudgetofthatslotisex ceededandtheShMSwouldnotbeableto
grantpowertothatAMC.