Specifications

6
Troubleshooting
102
Investigating sensor values
Toviewthesensorvalueforasensorthathasgeneratedanalarm:
1. WritedowntheFRUslotidentifiedbythealarmandtheseverityofthealarm.
2. IntheplatformmanagementCLI,toaccessthefrontmodeofanidentifiedslotenter:
3. DisplaytheeventlogfortheFRUusingthecommandshowwiththeeventsoption.
4. Locatetheeventthatcorrespondstothealarm.Theeventincludesthesensornameand
value(state).
Toviewthevalueofaknownsensor.
1. IntheplatformmanagementCLI,accesstheslotmodeoftheFRUcontainingthesensor.
2. Displaythesensorusingthecommandshowwiththesensorsoption.
Note:ToinvestigatesensorsthatapplytotheShelfManager,usetheshelfmanagement
modecommandshowsensors.
Viewing temperature readings
To view temperature readings for a FRU
1. IntheplatformmanagementCLI,accessthefrontmodeoftheFRUcontainingthesensor.
2. Displaythesensorusingtheshowcommandwiththesensorsoption.
To view approximate temperature readings for the shelves
On the ATCA-6000 shelf:
EachSPMhastwosensorstomeasuretheintaketemperature,andeachfanhasanexhaust
temperaturesensor.Checktheintaketemperaturesandcomparethemtotheexhaust
temperatures,asfollows:
1. UsehpiapptoquerytheresourceIDofanSPM:
hpiapp
3
0
Syntax:
front<slot_num>
Syntax:
show{eventsall|informational|minor|major|critical}
Syntax:
showevents{all|informational|minor|major|critical}
Syntax:
show{sensors{all|sensorId<id>}}
Syntax:
show{sensors{all|sensorId<id>}}