Specifications

B
IPMI Commands and Managed Sensors
89
OEM command descriptions
SpecialcommandsareavailabletofacilitateCPMspecificfunctionality.Thefollowingsections
describetheCPMOEMcommands.
Restore Factory Defaults command
Thiscommandrestoresthefactorydefaultconfigurationandthresholdparametersfor
onboardsensors.Table 27isthecommanddescriptionoftheRestoreFactoryDefaults
command.
Set Control State command (for debug only)
Thiscommandoverridesthecurrentfirmwaresettingofthecontrolpinandshouldtherefore
onlybeusedindebugsituationsandneverforproductioncoding.Table 28isthecommand
descriptionoftheSetControlStatecommand.
*Restore Factory Defaults OEM Group (2Eh) OEM 1(30h) 05h
*Disable CFD OEM Group (2Eh) OEM 1(30h) E7h
*Set WDT Reset Type OEM Group (2Eh) OEM 1(30h) A8h
*Switch Active Boot Flash OEM Group (2Eh) OEM 1(30h) A9h
*Get Active Boot Flash OEM Group (2Eh) OEM 1(30h) AAh
*Set Control State (for debug only) OEM Group (2Eh) OEM 1(30h) 20h
*Get Control State(for debug only) OEM Group (2Eh) OEM 1(30h) 21h
* Refer to OEM command descriptions on page 89
Table 26. Supported IPMI Commands (continued)
IPMI Command name NetFn Code Command Code
Table 27. Restore Factory Defaults OEM command
Data Type Byte Data Field
Data Field
NetFn 0x30
Command 0x05
N/A
Response Field 1 Completion Code
Table 28. Set Control State OEM command
Data Type Byte Data Field
Data Field
1 FRU ID
2 Control number
3 Control State
00h = de-assert
01h = assert
02h = pulse de-assert
03h = pulse assert
Response Field 1 Completion Code