Specifications
5
Chapter
69
Troubleshooting and Repair
Introduction
Theprocedurespresentedorreferencedinthischapterdetailremovalandreplacementof
CPMFieldReplaceableUnits(FRUs)andprovidetroubleshootingproceduresthatcanbeused
todiscoverFRU’sthatneedtoberepairedorreplaced.ThefollowingCPM‐relateditemscan
beinstalledorreplaced:
•TheCPMitself.Forinstallationinstructions,seetheATCA‐4xxxComputeProcessing
ModuleInstallationGuide.Forreplacementinstructions,seeCPMreplacement
proceduresonpage 71.
•TheDIMMs.Forplacementinformationandinstallationandremovalinstructions,see
Memorymodulereplacementproceduresonpage 73.
•AnMXMmodule.Forinstallationorremovalprocedures,seeMXMmodule
installation/replacementproceduresonpage 75.
•TheeUSBmodules.Forinstallationorremovalprocedures,seeeUSBmodule
installation/replacementproceduresonpage 76.
•AcompatibleRTM.Forinstallationandremovalinstructions,seetheRearTransition
ModuleInstallationGuide.
RefertoTroubleshootingTopicsonpage 77fortroubleshootingprocedurestouseonthe
CPM.
Field Replaceable Units (FRUs)
FRUinformationisstoredinnon‐volatilememoryandisusedbytheIPMCtolocateand
communicatewiththeavailableFRUs.TheCPMstoresitsFRUinformationincompliancewith
thesespecifications:
• IPMIPlatformManagementFRUInformationStorageDefinition,v1.0,Revision1.1
•PICMG3.0Revision2.0AdvancedTCABaseSpecification
The
rsys‐ipmitoolutilitycanretrieveallFRUinformation,includingbackplaneE‐Keyingand
on‐boardE‐Keyinginformation.
FRU information areas used
TheCPMprovidesthisFRUinformation:
•Commonheader
•Internalusearea
•Boardinformationarea
• Productinformationarea
• Multirecordarea