Specifications

4
Operation and Maintenance
66
Establishing a SOL session
Prerequisite:ThisprocedureassumesthattherequiredsetupforIPMIoverLANhasbeen
doneonceforthisCPM.Fordetails,seeConfiguringIPMIoverLANaccessonpage 63.
One-time SOL configuration steps
ThefollowingtwostepsconfiguretheCPMforSOL:
1. IntheCPMBIOSSetup,changetheactiveserialporttoCOM1,asfollows:
AdvancedSettings>SerialPort1Configuration>Serialport:Enabled
2. SettheLinuxconsoleparameterstoCOM1(ttyS1)tosupportSOL.
Toconfigureretrysettingsfromaremotecomputer:
Important:Fortheseonetimesteps,usetheRadisyssuppliedrsysipmitoolutility.
3. ConfiguretheretriestokeepSOLsessionsopenforaBaseinterfaceIPaddress.
rsysipmitool‐I<protocol>‐H<IP>‐Anone‐C0solsetretryinterval0xF0
rsysipmitool‐I<protocol>‐H<IP>‐Anone‐C0solsetretrycount7
Foranexplanationof<protocol>and<IP>,seeBeforeyoubeginonpage 63.
4. RepeatStep toconfigureretriesfortheotherBaseinterfaceIPaddress.
5. ViewtheretrysettingsforaBaseinterfaceIPaddress.
rsysipmitool‐I<protocol>‐H<IP>‐Anone‐C0solinfo
Theretrycountshouldbe7,andtheretryintervalshouldbe2400ms.
6. RepeatStep 5toverifyaccesstotheremaininginterfaceIPaddresses.
7. TheSOLpayloadisdisabledbydefault.Enterthefollowingcommandtoenableit:
rsysipmitool‐IlanplusH<IP>‐Anone‐C0solpayloadenable
Note:ForproperSOLoperationduringBIOSPOSTandatOSruntime,theBIOSconsole,OS
console,andSOLbaudratesmustallagree.ThedefaultSOLparametersincludea38400baud
rateinsteadofthedefaultBIOSconsoleredirectionbaudrateof115200.The38400baudrate
mightbebetter
atavoidingcharacterdropsduringaSOLsession.
8. Boththevolatileandnonvolatilebitratesmustbesettothesamevalue.Enterthe
followingcommandstosetthebaudrateto115200:
rsysipmitool‐Ilanplus‐H<IP>‐Anone‐C0solsetnonvolatilebitrate115.2
rsysipmitool‐Ilanplus‐H<IP>‐Anone‐C0solsetvolatilebitrate115.2