Specifications
B
IPMI Commands and Managed Sensors
106
94 Boot Error Boot Error Sensor-
specific
N/A Offset Description
00h = Boot Record Corruption
eventData1
: 0xA0 - Boot record corruption
eventData2
: 0x00 - Currently executing Application
image does not match non-volatile storage
designation
eventData3
: 0x00 - Currently executing Application
image does not match non-volatile storage
designation (i.e., running != active)
01h
= Boot Failure (IPMC Boot Error)
eventData1: 0xA1 - Boot failure error
eventData2
: 0x00 - Currently executing Application
image does not match non-volatile storage
designation
eventData3
:
Bits 7:4 == Currently executing Application image
number
0x1 - Bank 1
0x2 - Bank 2
Bits 3:0 == Image number specified in non-volatile
boot record (active)
0x1 - Bank 1
0x2 - Bank 2
02h
= Application Image Corruption (IPMI-FW Application
Image Corruption)
eventData1
: 0xA2 - Application Image Corrupt
eventData2
: Currently executing Application Image#
0x11 - Bank 1
0x22 - Bank 2
eventData3
: Corrupted Application image#
0x11 - Bank 1
0x22 - Bank 2
95 System Event System Event Sensor-
specific
N/A Offset
Description
01h = OEM System Boot Event
05h
= Timestamp Clock Synch
96 OEM HPM Event OEM (0xEF) Sensor-
specific
N/A Offset
Description
00h = No bootable media)
97 OEM CFD
Watchdog
Watchdog 2 Sensor-
specific
N/A Offset
Description
03h = Power Cycle
98 Arbitration OEM SHMC HA
State
Sensor-
specific
N/A Offset
Description
00h = IPMC Redundancy State (Only applicable if CPM is
in IPMB Addr 0x82 and acts as shelf manager)
eventData1
: 0
eventData2
: Current State (10 = active)
eventData3
: Previous State (03 = standby)
Table 38. ATCA-46xx IPMI Managed Sensors (continued)
Sensor
#
Name Type
Reading
Type
Normal
Reading
Notes