User manual
Appendix C
C-3
PLC-5/VME
t
Processor Specifications
PLC-5/V30
t
(1785-V30B)10.
PLC-5/V40
t
(1785-V40B)
PLC-5/V40L
t
(1785-V40L)
PLC-5/V80
t
(1785-V80B)
Maximum User Memory Words 32 K
48
K
➀
100
K
➀
Maximum
Any Mix 896
1920 2944
Maximum
Total I/O
Complementary 896 in and 896 out
1920 in and 1920 out 2944 in and 2944 out
Maximum Analog I/O 896 1920 2944
Program Scan Time
0.5 ms per K word (bit logic)
2 ms per K word (typical)
I/O Scan Time
0.5 ms (extended local)
10 ms per rack @ 57.6 kbps
7 ms per rack @ 115.2 kbps
3 ms per rack @ 230 kbps
RIO Transmission Rate
57.6 kbps
115.2 kbps
230 kbps
Maximum Number of MCPs 16
Number of Data Highway Plus
t
(DH+
t
)
or Remote I/O Ports (Adapter or Scanner)
2 4 2 4
Number of Extended-Local I/O Ports N/A N/A 1 N/A
Maximum Number of I/O Racks 7 15 23
Maximum Number
Extended Local
N/A N/A 16 N/A
Maximum
Number
of I/O Chassis
Remote
28 60 92
Number of RS-232 Ports 1
Backplane
Maximum
3.0 A 3.3 A 3.5 A 3.3 A
Backplane
Current Load
Typical
2.4 A 2.7 A 2.9 A 2.7 A
Weight 0.56 kg (1.25 lbs) 0.67 kg (1.5 lbs)
➀