User manual
Chapter 1
Overview
1-5
The following diagrams show three basic configurations for programming
and debugging your ladder-logic programs.
Connect
a computer via the DH+ link, typically using a
1784-KT communication device in your IBM A
T
computer
and a 1784-CP6 cable.
Connect a computer using the RS-232C on-board serial
port of the PLC-5/VME processor
. In this configuration, the
RS-232C cable connects one of the computer
’
s COM ports
to the channel 0 (serial) port of the processor
.
Y
ou can program as well as download files directly over the
VMEbus backplane to your PLC-5/VME processor if you:
run 6200 Series PLC-5 Programming Software release
4.4 or later
use an 8086-based CPU from RadiSys—i.e., a EPC-1,
EPC-4, or EPC-5 VME PC-compatible computer
.
Important:
In order to use the
save
feature of the 6200
Series PLC-5 Programming Software when you
communicate with the processor in this way
, you must run
release 4.5 or later
.
19501
DH+ link
PLC-5/VME
processor
PLC-5/VME processor
PLC-5/VME processorPC/CPU
RS-232