4.0 Special D6600 NetCom Applications
The following are special applications that have been requested by Bosch Security Systems dealers. They are included here
to assist you should you have the same requirements. If you have any questions, please feel free to contact Technical
Support at (888) 886-6189.
4.1 Emulating a Direct Serial Connection Over a LAN Using D6680 Network Adapters
In some applications it may be required that a direct serial connection be emulated over the network. One application
that would require this is where the D6600 Receiver is located on another part of the network from the Automation
System. We can take the COM3 automation output from the D6600 and using two D6680’s we can pipe a direct serial
connection between the D6600 and the Automation System. This is true serial cable emulation over the network (see
Figure 5).
D6600
Receiver
D6680
#1
D6680
#2
Automation
System
192.158.001.017 192.168.001.016
COM3
Ethernet
RS232
Figure 5: Direct Serial LAN Connection Configuration
The commands necessary for this configuration to automatically establish this connection are as follows. Note the
reference to the D6680’s by their number (#1 or #2). You will also need to insure that the port parameters such as speed,
number of bits, flow control etc. are correct on the D6680 for the serial device that they are connected to.
D6680 #1:
*** basic parameters
Hardware: Ethernet TPI
IP address: 192.168.001.017, no gateway set
******* Channel 1 *******
Baudrate 9600, I/F Mode 4C, Flow 00
Port 7700
Remote IP Adr: 192.168.001.016, Port 7700
Connect Mode: C0
D6680 #2:
*** basic parameters
Hardware: Ethernet TPI
IP address: 192.168.001.016, no gateway set
******* Channel 1 *******
Baudrate 09600, I/F Mode 4C, Flow 00
Port 7700
Remote IP Adr: 192.168.001.017, Port 7700
Connect Mode: C0
For more information, refer to the D6680 Network Adapter Installation Guide (P/N: 4998138732).