Installation guide

D6600/D6100 | Operation and Installation Guide | 16.0 Specifications
34 Bosch Security Systems | 4/05 | 4998122704F
16.0 Specifications
Table 12: D6600/D6100 Specifications
Rack mount (2U)
18 cm x 48.3 cm x 49.5 cm
(7.0 in. x 19.0 in. x 19.5 in.)
D6600
Standalone
18 cm x 45.0 cm x 49.5 cm
(7.0 in. x 17.75 in. x 19.5 in.)
Rack mount (1U)
9.0 cm. x 37.5 cm. x 25.5 cm
(3.5 in. x 19 in. x 10 in.)
Dimensions
(H x W x D)
D6100
Standalone
9.0 cm. x 30.5 cm. x 25.5 cm
(3.5 in. x 12.0 in. x 10 in.)
D6600 8.7 kg (19 lb)
Weight
D6100 3 kg (7 lb)
Cabinet Finish
Aluminum, dark gray, semi-gloss enamel.
AC Nominal Operating Range 120 V or 230 V
Power Input
AC Maximum Operating Range
100 VAC to 120 VAC, 220 VAC to 230 VAC, 50/60 Hz
2.5 A maximum
Required battery current 800 mA D6600 with one line card installed
Required UPS AC standby current 350 mA
Required additional battery current 210 mA
For each additional line card or terminal
card pair
Required additional UPS AC standby current 35 mA
Required additional battery current 10 mA For network communications card
Required additional UPS AC standby current 10 mA
Required battery current 330 mA
Current Required
D6100
Required UPS AC standby current 180 mA
Standby Power
Use a UPS with the D6600/D6100. The receiver includes an external battery connection and battery harness. Use
12 V rechargeable sealed lead-acid batteries. A 4-hour minimum standby power supply (UPS or battery) is required
for UL Certification (refer to Section 8.1 Connecting External Batteries on page 14 for battery size).
Telephone
RJ11C modular jacks, with 26 AWG or larger wire diameter.
ESVUSA-25328-AL-N
The D6600 Receiver is Federal Communications Commission (FCC) registered under Part No. 68 using the
RJ11C Interconnect that can be ordered from your local telephone company.
FCC Registration
Notice: This equipment was tested and found to comply with the limits for a Class “A” digital device, pursuant to
Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy, and if not installed according to the instruction manual, might cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which
case the user must correct the interference at his or her own expense.
Ringer Equivalence
0.4 B
Screen size: (H x W) 0.7 in. x 6.0 in. (1.8 cm x 15.2 cm) dot matrix LCD (5 x 7 dots per character).
Shows two separate lines of 40-characters each.
Display
LED LED display section indicates receiver status and power.
Inputs and Outputs
One RS-232 interface port COM3 (middle connector on the CPU terminator card) for connection to an
automation computer.
One RS-232 interface port COM4 (upper connector of CPU terminator card) for connection to an external
serial printer, a PC, a modem, or a network.
One parallel printer port for connection to a parallel printer
Two programmable inputs (wire harness included)
Two programmable outputs (wire harness included)
Optional: One RS-232 port (COM1) for the Network Communications expansion option (D6600 only).
Austel Approved
CE Approved
- CTR-21
- EN60950 Safety
- EN55022 Radiated/
Conducted Emissions
Listings and
Approvals
(D6100 Listings and
Approvals are
pending)
UL Central Station Fire (864)
UL Central Station Burglary (1610)
UL Police Station Connect (365)
FCC Part 15 Radiated/Conducted Emissions
FCC Part 68 Telecom
ULC
Industry Canada
NIST AES Certification