S-Series OmniCell@Home Picocell GSM Implementation Guide Specifications
998-1027-01 Rev X2
Table 8 Power Requirements
Min Nom Max Units Comments
Operational 11.4 12 12.6 VDC
Required range for normal operation of the
PicoBTS
Operational
1.43 1.25 1.58
A
Operational 8.3 – 13.2 VDC
PicoBTS will power up, but may not function
properly
Operational 1.36 – 2.17 A
Absolute Max – – 15 VDC
Exceeding may cause permanent damage
Absolute Max – – 2.2 A
Absolute Min 7.9 – – VDC
Below this voltage the PicoBTS will not power up
Absolute Min 1.2 – – A
3.4 Output Power
The PicoBTS is configured for an output power of:
• GMSK +23 dBm max
• 8-PSK +15 dBm max
3.5 Power Control
Transmit power control is statically provisioned in 2 dB ± 1 dB steps according to GSM
05.05, sub clause 4.1.2.
3.6 Typical Coverage Area
The typical coverage radius measures approximately 50 m. Nominal coverage per
PicoBTS is 6,360 sq m (70,000 sq ft).
3.7 Heat Load
Table 5 identifies the heat load for a functional PicoBTS.
Table 9 Heat Load
Component
Heat Load
(W) (BTU per Hour)
PicoBTS
18 61.45
3.8 RF Performance
The PicoBTS employs dual-band transceivers, which for the European market includes
GSM900 (GSM) and GSM1800 (PCS) and for the North American market includes
GSM850 and GSM1900.
RadioFrame Networks, Inc. SUPPLIER AND CUSTOMER INFORMATION 15