User's Manual

Hardware Specifications
37
RadioFrame Unit
Certified to 47 CFR Part 90. Licensed operation required. Radiofrequency
exposure approved for fixed installations only. The antenna used for this
transmitter is integral to the unit. The radio and its associated antenna are to be
fixed-mounted on indoor permanent structures providing a separation distance
of at least 20 cm from all persons during normal operation and 10 feet from other
RFU mounted assemblies. The maximum radiated output power at the antenna
must satisfy the MPE Categorical Exclusion Requirements of 2.1091. The
maximum radiated output power of any antenna shall not exceed 100mW. RF
exposure compliance may need to be addressed at the time of licensing, as
required by the responsible FCC Bureau(s), including antenna co-location
requirements of 1.1307(b)(3).
Operating Environment
Operating Ambient Temperature: 0
o
C to +40
o
C (+32
o
F to +104
o
F)
Storage Temperature: -40
o
C to +70
o
C (-40
o
F to +158
o
F)
Relative Humidity: 10-90% non condensing
Altitude: -200 to +8000 feet above mean sea level; above 8000', reduce
maximum operating ambient temperature by 2
o
C per 1000' to a maximum of
13000'
Shock: 40 g’s
Vibration: Level 3 earthquake
Keep product free from dust, wind, salt, liquids
Agency Compliance
FCC Part 90 CSA 22.2 No. 60950
ISTA 2A transit
Physical Specifications
Dimensions: 13.5" wide x 8" high x 5" deep (approx.)
Weight: 3 lbs (approx., no cards)
Input Power
Negative 36-56 Volts DC, 0.8A