User's Manual

Installing the RadioFrame System
18
Install the RFUs
RadioFrame Units are all installed on a wall or on or above the ceiling. First,
mount an RFU, then connect it to the ACU and verify that the RFU is receiving
power from the ACU. Then, insert the RadioBlades into the RFU in the
configuration specified in the Site Design Specification (SDS).
Warning!
The RadioFrame Unit (RFU) is to be fix-mounted on indoor permanent
structures providing a separation distance of at least 20 cm from all persons
during normal operation and 10 feet from other RFU mounted assemblies.
Mount the RadioFrame Units (RFUs)
1 Find these items in the RFU shipping container: one RFU, mounting screws and
anchors, two mounting templates (wall and ceiling), and one ceiling bracket.
2 Complete one of the following procedures, “Wall Mount” or “Ceiling Mount” for
the specified location of the RFU.
Warning!
Do not touch the backplane (board) inside the RFU. A shock may
result.
Wall Mount
1 Place the 11” x 17” drawing template (P/N 981-1020-00) on the wall where the
RadioFrame Unit is to be mounted.
2 Mark the two locations indicated on the template.
3 Screw the two supplied anchors into the locations as shown.
4 Screw the two supplied screws into the anchors, leaving approximately 1/4” of
each screw exposed.
5 Hang the RFU on the anchors and fully tighten both screws.