5-10 ©2008 RadioFrame Networks, Inc. MC-Series
Proprietary and Confidential Information
5.3.5 defaultTxPower
Note: Refer to release notes for the proper range
information.
This is the average output power of the PA, measured at the RF connector of the
BR. For the MCSC system, this parameter can be used to adjust the output power
of the system. The gain at the shelf is fixed and cannot be altered. The MCSC
system has a different range of output levels than a standard Motorola EBTS, and
as such, these values will map to a different set of actual Tx output power levels.
Refer to the Datafill Guide for the values and more information.
5.4 System Manager, Configuration, and Optimization
5.4.1 Navigating System Manager
A. Logging into System Manager
1. Connect a laptop computer to port 7 of the ABIC CRIC using an Ethernet
(Cat-5) cable.
2. Start System Manager by typing the IP address of the MCSC system into
Internet Explorer (default 192.168.200.5).
3. The System Manager Home page appears and displays five tabs to select
from to set up and monitor the RadioFrame MCSC system.