MC-Series Standard Capacity system
998-1019-01 Rev X1
Figure E-1 BER Test Flow
E.5 Equipment Connection/Setup
Set up the equipment to measure Rx BER as follows:
1. Connect a laptop to port 8 of the ABIC CRIC using an Ethernet (CAT-5) cable.
2. Boot the laptop, start System Manager and log in.
3. Launch a browser session and then enter the MCSC system IP address (http://
192.168.200.5). Select the Performance Monitoring tab to display the login
window. Type the User Name, (
Sysadmin, case sensitive), and Password
(
Radioframe, case sensitive), and then select OK.
4. Connect Signal Generator to MCSC system