User's Manual

MC-Series Standard Capacity system
998-1019-01 Rev X1
9-10 ©2008 RadioFrame Networks, Inc. MC-Series
Proprietary and Confidential Information
6. Reconnect the cabling to the replacement chassis as defined in Step 2 .
7. Using the breakers on the PDU, turn up the ABIC and DRBS and then verify
that the components are operational before proceeding.
a. Wait approximately 3 minutes for the following indicators:
DRBS:
The STATUS LED for each group will turn green in this order: A, B, and
then C.
The RADIOBLADE TRANSCEIVER STATUS LEDs will turn red and then
green for each present RadioBlade transceiver. If no RadioBlade
transceiver is present, the LED will not light. To verify the contents of the
DRBS, pull out the shelf (powering off is not required) and inspect the
RadioBlade transceivers and their respective status LEDs. Reinsert the
DRBS. To do this, press up on one side rail locking arm and press down
on the other side rail locking arm, and then push the unit into the cabinet.
For an illustration of the locking arms, refer to Figure 9.13.
BIC CRIC:
The POWER and STATUS LEDs will turn red and then green. All other
ABIC card LEDs will turn green.
8. Using the breaker on the PDU, turn up the RF Shelf and then verify it is
operational before proceeding. The POWER and ALARM LEDs on the front of
the RF Shelf will turn green.
9. Complete the procedures in sections 5.2 (System Setup) and Appendix C
(Functionality Test Procedures).
9.4.2 DRBS
1. Power down RadioFrame Networks equipment in the following order using
circuit breakers on the PDU:
•BIC
DRBS
RF Shelf 1
RF Shelf 2
RF Shelf 3
2. Disconnect cabling from the back of the DRBS to be replaced.