Table 8.7 Alarm Code 4133 Properties
Table 8.8 Maximum BR derated TxPower
8.4.3 System Manager Alarms
The document Alarms/Events Reference Guide lists MCSC system alarms
numerically by alarm ID (0x01, 0x02, etc.).
MC-Series alarms are based on the X.733 conventions for telecommunications
equipment. The alarms are grouped by service: either “asp” for platform faults or
“iden” for iden application faults. The “cause” field contains the X.733 cause type.
“System reaction” describes the action taken by the system as a result of this
alarm, and “repair actions” provides details on what corrective action should be
taken as a result of this alarm.
The Alarm details on the active alarm manager page of System Manager provides
additional information with respect to the board, slot number, MAC address and
equipment type.
Event Description
Alarm Code 4133
Event Type iDEN
Severity Major
Cause Configuration Customization Error.
System reaction Set the default TX power to 9.2.
Additional Info Session ID
Repair Action
In a configuration where the number of carriers per sector
exceed six, the default TX power can’t exceed 9.2.
Reconfigure the default TX power to a value of 9.2 or less.
MC-
Series
Max # Of
Carriers/
Sector
Max Power Output per
Carrier @ 6 carriers with
defaultTxPower set to 9.5
New de-rated
Power at 9.2
Standard
Capacity
12 2W 1W