8.3 Hardware Alerts
8.3.1 Fault Indications
This section provides fault indications for the following RadioFrame Networks
components only: ABIC, DRBS and RF Shelf. For all non-RadioFrame Networks
equipment, refer to or the manufacturer’s documentation.
8.3.2 ABIC Indicators
Table 8.1 BIC LED Indications
LED Indication Condition Corrective action
POWER
green normal condition none
not lit no power to ABIC
• Verify that ABIC circuit breaker on PDU is
ON.
• Check power connection to PDU.
• Measure power input, and compare with
tolerances listed in Chapter 2
(Specifications).
• Verify that the power source is
operational.
• Contact the TAC: (800) 328-0847
STATUS
green normal condition none
not lit card(s) not receiving power
• Verify power to ABIC (see “no power to
ABIC” above)
red
CRIC only
bootup not complete
• Allow three minutes (approx.) for bootup
to complete.
timing not synchronized
• Verify that the GPS LED on iSCIII is
green.
• Verify that the cable is connected from
ABIC ERTM port 5MHz/1PPS IN to iSCIII
port 5MHz/1PPS.
• Contact the TAC: (800) 328-0847
red
any card
PLLs are not locked
• Verify that the STATUS LED on the ABIC
CRIC is green
• Check the Alarm Manager for PLL LOCK
alarm; wait 3 minutes for PLLs to lock; if
they do not:
• Verify integrity of the ABIC Ethernet
connection.