6-foot Cat-5 (or 5e/6) Ethernet cable (EIA/TIA 568B) to connect to the ABIC
CRIC
Straight-through, male-to-female serial cable (DB9/RS232)
50 ohm 2W terminating loads for all RF ports to be used according to the
site configuration
Ensure that the following RadioFrame Networks software is available:
CD ROM (backup)
New versions can also be downloaded from RadioFrame Networks web site
to the local root directory (C:/)
For local software downloads, have the following available on the laptop:
FTP server software—WFTPD32 is shareware that can be downloaded
from the following site: http://www.wftpd.com/
Terminal emulation software (e.g., PROCOM)
7.1.2 Checkout Procedures
1. Verify that all breakers in the PDU are in the OFF position prior to proceeding.
Leave them in the OFF position until instructed otherwise.
2. Conduct a visual inspection of the cabling on the rear of the cabinet verifying
that all connections are in place, tight, and complete.
3. Add and remove RadioBlade transceivers according to the site configuration.
Refer to section 9.7 (RadioBlade Transceiver Replacement).
4. Verify that cabling matches the site configuration.
5. Refer to Appendix C (MC-Series Standard Capacity system Cabling).
6. Install 50 ohm 2 W terminators on all unused Tx / Rx / Rx Diversity ports on the
rear of the enclosure.
7. Verify that there is DC power at the supply terminals on the PDU and that the
polarity is correct. Refer to section Chapter 2 (Specifications) for more
information.
Caution!
Verify that all breakers in the PDU are in the OFF position prior to proceeding.
Leave them in the OFF position until instructed otherwise.