5-10 ©2007 RadioFrame Networks, Inc. MC-Series
CONFIDENTIAL AND PROPRIETARY
Table 5.6 Alarm Code 35009 Properties
iDEN Alarm Code 4133
The Pole Mount system also introduces a new iDEN alarm (4133). Table 5.7
shows the properties for this alarm code.
In an OPM system with greater than 6 carriers provisioned in a sector, the default
TX power cannot exceed 9.2. It is necessary, therefore, to reconfigure the default
TX power to a value of 9.2 or less.
If more than 6 carriers are provisioned in a single sector AND the defaultTxPower
exceeds 9.2 on any of those BRs, then the maximum allowable TX Power will be
de-rated for the BRs in that Sector as shown in Table 5.8.
Event Description
IIOF Alarm Code 35009
Event Type CntrlBrd
Alarm Type Equipment Failure
Actionable Yes
Severity Minor, Major or Critical
Bounce Threshold (x) 3
Bounce Threshold Minutes 30
Duration Threshold 10
Related Alarms None
R & C RC
Outage Y/N S1_El CY
Event Description Unable to key BR
Advisor Site Service call
Comments None
Alert Names BREFCTLBD35009
Last updated 8/3/2001
Revision
Change Notes
8/3/2001: per new EBTS rules baseline.
Changed severity and threshold from GR1 to:
Severity=minor
BounceThreshold=3
Bounce Threshold Minutes=30
Duration Threshold=10
Action
Create trouble ticket.
Contact Field Technician.
TS/BR