User's Manual
MC-Series Outdoor Pole Mount Users Guide998-5005-01 Rev X1
MC-Series ©2007 RadioFrame Networks, Inc. 5-5
CONFIDENTIAL AND PROPRIETARY
5.3.3 DRBS Indicators
Table 5.2 DRBS LED Indications
5.3.4 OPM RF Shelf Indicators
LED Indication Condition Corrective action
STATUS
green normal condition none
not lit no power to DRBS
• Verify that DRBS circuit
breaker on PDU is ON.
• Check power connection to
PDU.
• Measure power input, and
compare with tolerances.
• Verify that the power
source is operational.
• Contact the TAC: (800)
328-0847
red
timing is not synchronized to
the group (A, B, or C)
Board unable to boot
• Power cycle the DRBS
using the circuit breaker on the
PDU.
• Contact the TAC: (800)
328-0847
RADIOBLADE
TRANSCEIVER
STATUS
green
RadioBlade transceiver
present and operational
none
not lit
RadioBlade transceiver not
present
none
RadioBlade transceiver
present
• Reseat RadioBlade
transceiver.
red
RadioBlade transceiver is in
error state
• Reseat RadioBlade
transceiver.
• If still red, replace
RadioBlade transceiver.