5.3.2 ABIC Indicators
Table 5.1 ABIC LED Indications
LED Indication Condition Corrective action
POWER
green normal condition none
not lit no power to ABIC
Verify that ABIC circuit breaker
on PDU is ON.
Check power connection to
PDU.
Measure power input, and
compare with tolerances.
Verify that the power source is
operational.
Contact the TAC: (800) 328-
0847
STATUS
green normal condition none
not lit card(s) not receiving power
Verify power to ABIC (see “no
power to ABIC” above)
red
CRIC only
bootup not complete
Allow three minutes (approx.)
for bootup to complete.
timing not synchronized
Verify that the GPS LED on
iSCIII is green.
Verify that the cable is
connected from ABIC ERTM port
5MHz/1PPS IN to iSCIII port
5MHz/1PPS.
Contact the TAC: (800) 328-
0847
red
any card
PLLs are not locked
Verify that the STATUS LED on
the ABIC CRIC is green
Check the Alarm Manager for
PLL LOCK alarm; wait 3 minutes
for PLLs to lock; if they do not:
Verify integrity of the ABIC
Ethernet connection.
Contact the TAC: (800) 328-
0847