User's Manual
MC-Series Outdoor Pole Mount Users Guide998-5005-01 Rev X1
MC-Series ©2007 RadioFrame Networks, Inc. 3-13
CONFIDENTIAL AND PROPRIETARY
3.3 Rollback to the previous version of software
Revert to a previous version of MC-Series OPM System software only if the upgrade
fails.
1. Select the Software Download & System Reset link on the System
Configuration page.
2. On the Software Download & System Reset page (Figure 3.9), under System
Reset, select the inactive partition to revert to the previously loaded version of
software.
3. Select the Reset System button.
This reboot will take several minutes to complete. Wait for the system to come
back, and then refresh the page or reopen the web browser to force the page
to update.
3.4 Performing a System Reset
1. If necessary, connect the laptop to the MC-Series OPM System, start System
Manager, and log in (for complete instructions, refer to section 2.2 (System
Setup)).
2. Select the Software Download & System Reset on the System Configuration
page.
3. On the Software Download & System Reset page (Figure 3.9), select the Reset
System button.
4. Follow the procedure in section 6.6 to add or remove a RadioBlade transceiver.