Appendix F BER Test Procedure
F.1 Bit Error Rate (BER) Diagnostic Test
The Bit Error Rate (BER) Diagnostic Test is used to execute BER tests of the MC-
Series OPM System. The Diagnostic Test supports multi-channel RadioBlade
(MCRB) transceivers in the 800E MHz band. BER testing gives a pass/fail
determination for each blade and should be performed on all blades in the Diversity
RadioBlade shelf (DRBS).
The most common testing scenario involves acceptance-test plan (ATP) execution
during incoming inspection and commissioning. The MC-Series OPM System can
be taken out of service for testing during a maintenance window. The RadioBlade
transceivers can be locked as a group and then unlocked one-by-one for the BER
tests.
F.2 Prerequisites for Testing
These procedures presume that the MC-Series OPM System is in place at its site of
service and operational. Therefore, the prerequisites for operation will already have
been satisfied:
The T1 is live and has been tested.
The datafill has been completed, including BR Cabinet and position
assignments, and conforms to the recommended datafill.
All site cabling and installation work has been completed and all punchlist items
corrected.
The system is powered and operational.
The software is at least Revision 14.x.xxx.
In addition, the following conditions are required for BER testing:
The BER test requires that the RadioBlade Shelf be connected to an ISC.