Appendix F BER Test Procedure
F.1 Bit Error Rate (BER) Diagnostic Test
The Bit Error Rate (BER) Diagnostic Test is used to execute BER tests of the MC-
Series OPM System. The Diagnostic Test supports multi-channel RadioBlade
(MCRB) transceivers in the 800E MHz band. BER testing gives a pass/fail
determination for each blade and should be performed on all blades in the Diversity
RadioBlade shelf (DRBS).
The most common testing scenario involves acceptance-test plan (ATP) execution
during incoming inspection and commissioning. The MC-Series OPM System can
be taken out of service for testing during a maintenance window. The RadioBlade
transceivers can be locked as a group and then unlocked one-by-one for the BER
tests.
F.2 Prerequisites for Testing
These procedures presume that the MC-Series OPM System is in place at its site of
service and operational. Therefore, the prerequisites for operation will already have
been satisfied:
• The T1 is live and has been tested.
• The datafill has been completed, including BR Cabinet and position
assignments, and conforms to the recommended datafill.
• All site cabling and installation work has been completed and all punchlist items
corrected.
• The system is powered and operational.
• The software is at least Revision 14.x.xxx.
In addition, the following conditions are required for BER testing:
• The BER test requires that the RadioBlade Shelf be connected to an ISC.