User's Manual
MC-Series Outdoor Pole Mount Users Guide
998-5005-01 Rev X1
D-6 ©2007 RadioFrame Networks, Inc. MC-Series
CONFIDENTIAL AND PROPRIETARY
Table D.8 Dispatch Connection Stability Worksheet
D.7 Idle SQE Testing and Validation
Using the iFTA tool in “Single Cell” mode, record the idle RSSI and SQE values for
the control channel for at least one hour per sector, while the mobile remains fixed.
D.8 System Self-Recovery Test
The following test is to determine the ability of the MC-Series OPM System to
recover from various iSC-3 conditions.
Loss of T1
While the MC-Series OPM System is operating, disconnect the T1 connection
to the iSCIII for one minute, and then reconnect it. Monitor the system
recovery, and then validate the system by placing a successful call on each
sector.
iSCIII Power Loss
While the MC-Series OPM System is operating, the iSCIII shall be power
cycled and system recovery will be monitored and validated by placing a
successful call on each sector.
Loss of GPS
While the MC-Series OPM System is operating, the GPS connection to the
iSCIII will be disconnected until all Satellites are lost and then reconnected.
System recovery will be monitored and validated by placing a successful call
on each sector.
New datafill download
System recovery will be verified by pushing a new datafill download to the
iSCIII.
Dispatch #1 Carrier # RSSI (dB) SQE (dB) Sector Quality (1-5) Duration (min)
3
Dispatch #2
4
Dispatch #3
5