5. Connect the RadioFrame Networks-provided power cable (P/N 820-0613-50;
PDU-CTRL_1 to ISC1) between the iSCIII power and the CTRL1 circuit breaker
on the PDU.
6. Connect the RadioFrame Networks-provided ground cable (P/N 820-0609-10;
ISC1 to GND BAR) between the Cabinet ground bar and the grounding lug on
the rear of the iSCIII, and ensure the connection is tight.
7. Connect the iSCIII according to IIOF’s installation procedure.
8. Refer to Figure 1.2. Using the RadioFrame Networks-provided coax cable (P/N
111-0001-02;ABIC-ERTM 5 MHz IN to iSCIII REF OUT-1), connect the iSCIII
port SITE REF OUT 1 [K] to the ABIC ERTM port 5 MHz IN [L].
9. Terminate the two remaining SITE REF OUT ports on the iSCIII.
10. Using the RadioFrame Networks-provided coax cable (PN 111-0001-02; ABIC-
CRTC to iSC1 REF OUT-1), connect the iSCIII port 10B2-1 to CRTC port
10Base2 iSCIII.
11. Terminate the two remaining iSCIII 10B2 ports on the iSCIII.
Note: Figure 1.2 does not show all cabling. For
complete cabling information, refer to Appendix C
(OPM iDEN Microcell Cabinet Stack-Up
Configuration).