User's Manual
MC-Series System Installation & Testing
Scheduled and Unscheduled Maintenance
80 RadioFrame Networks, Inc.
Service: iden
Severity: minor
Cause: Equipment Malfunction
System Reaction: RB moved to standby state. BR may be Disabled.
Additional Info: RB Index
Repair Action: This happens when the system is no longer able to communicate with the Radio
Blade. Reseat RadioBlade, Move to different slot, check RBS/AIC connection. Replace
RadioBlade.
7.4.4.29 APC failed to sync with NPC
ID: 4100
Service: iden
Severity: critical
Cause: Equipment Malfunction
System Reaction: System Reset
Additional Info: None
Repair Action: If alarm does not clear, check cabling between AIC and BIC. Replace BPC. This
could be a result of a timing problem on the CRIC or backplane as well.
7.4.4.30 DSP Tx Packet Failed
ID: 4101
Service: iden
Severity: critical
Cause: Loss of Signal
System Reaction: System Reset
Additional Info: dsp index 1..16
Repair Action: Previously called DSP 1180 FLOODING. If happens at startup then check the RB
and try power cycling RB or RFU. Ignore if happens infrequently. If alarm does not clear or alarm
happens frequently,
- Reseat SPAM.
- Replace BPC
7.4.4.31 DSP Rx Packet Failed
ID: 4102
Service: iden
Severity: major