User's Manual

Scheduled and Unscheduled Maintenance MC-Series High-Power System
998--01 Rev X1
86 CONFIDENTIAL AND PROPRIETARY RadioFrame Networks, Inc.
TRADE SECRET INFORMATION
Figure 53 Serial Log Upload Page with IP Address Prompt
3 Copy the contents of the serial log window into a text file and save the text file.
4 Email the text file to the Technical Assistance Center at:
support@radioframenetworks.com
7.8 Power Down Procedure
When powering down the entire MC-Series system, follow these instructions.
Using the breakers on the PDU, power off equipment in the MC-Series system rack in the
following order:
BIC
AIC
RBS 1 (and RBS 2 if present)
RF Shelf 1, RF Shelf 2 and RF Shelf 3
CSU
Secondary iSC-3; then ensure that the power switch on the front of the unit is in the
OFF position
EAS; then ensure that the power switch on the front of the unit is in the OFF
position