MC-Series High-Power System Scheduled and Unscheduled Maintenance
998--01 Rev X1
RadioFrame Networks, Inc. CONFIDENTIAL AND PROPRIETARY 77
7.4.2 RBS
Table 23 RBS LED Indications
LED Indication Condition Corrective action
green normal condition none
not lit no power to RBS Verify that RBS circuit breaker on PDU
is ON.
Check power connection to PDU.
Measure power input, and compare
with tolerances listed in section
2.5,”Specifications”.
Verify that the power source is
operational.
Contact the TAC: (800) 328-0847
STATUS
red timing is not synchronized to
the group (A, B, or C)
Board unable to boot
Power cycle the RBS using the circuit
breaker on the PDU.
Contact the TAC: (800) 328-0847
green RadioBlade transceiver
present and operational
none
RadioBlade transceiver not
present
none not lit
RadioBlade transceiver
present
Reseat RadioBlade transceiver.
RADIOBLADE
TRANSCEIVER
STATUS
red RadioBlade transceiver is in
error state
Reseat RadioBlade transceiver.
If still red, replace RadioBlade
transceiver.
7.4.3 RF Shelf
Table 24 RF Shelf LED Indications
LED Indication Condition Corrective action
green normal condition none POWER
not lit no power to RF shelf Verify that RF circuit breaker on PDU is
ON.
Check power connection to PDU.
Measure power input, and compare with
tolerances listed in section
2.5,”Specifications”.
Verify that the power source is operational.
Contact the TAC: (800) 328-0847
green normal condition none
not lit not receiving power Verify power to RF Shelf (see “POWER”
above).
ALARM
red alarm condition Check the Alarm Manager for:
RF SHELF MINOR, replace fan.
RF SHELF MAJOR, replace RF shelf.
Contact the TAC: (800) 328-0847