User's Manual
Scheduled and Unscheduled Maintenance MC-Series High-Power System
998--01 Rev X1
76 CONFIDENTIAL AND PROPRIETARY RadioFrame Networks, Inc.
TRADE SECRET INFORMATION
7.4.1 ABIC
Table 22 BIC LED Indications
LED Indication Condition Corrective action
green normal condition none POWER
not lit no power to ABIC
Verify that ABIC circuit breaker on PDU is
ON.
Check power connection to PDU.
Measure power input, and compare with
tolerances listed in section 2
“Specifications”.
Verify that the power source is operational.
Contact the TAC: (800) 328-0847
green normal condition none
not lit card(s) not receiving power Verify power to BIC (see “no power to BIC”
above)
bootup not complete Allow three minutes (approx.) for bootup to
complete.
red
CRIC only
timing not synchronized Verify that the GPS LED on iSC-3 is green.
Verify that the cable is connected from BIC
ERTM port 5MHz/1PPS IN to iSC-3 port
5MHz/1PPS.
Contact the TAC: (800) 328-0847
STATUS
red
any card
PLLs are not locked Verify that the STATUS LED on the BIC
CRIC is green
Check the Alarm Manager for PLL LOCK
alarm; wait 3 minutes for PLLs to lock; if
they do not:
Verify integrity of Ethernet connection
between BIC and AIC.
Contact the TAC: (800) 328-0847