2.5.5 Power Consumption
Table 11 Power Consumption per Assembly (See Note)
Assembly Qty Power per
Assembly (W)
Total Power
(W)
Current
(A @ –48 VDC)
RF Shelf
3 532.7 1305.6 29.2
RBS (24 RadioBlade
transceivers)
1 67.2 67.2 1.4
BIC
1 110.0 110.0 2.3
AIC
1 115.2 115.2 2.4
ISC
2 24.0 48.0 1.0
EAS
1 19.2 19.2 0.4
CSU
1 40.0 40.0 0.8
TOTAL 1705 35.5
Note: Panduit termination lugs are required for installation. Wire size is AWG 6.
2.5.6 Grounding
Table 12 Grounding Resistance at Cabinet (TOR)(See Note)
Supplier Component Ground Resistance (Ω)
RadioFrame Networks
cabinet 0.6
Note: Panduit termination lugs are required for installation. Wire size is AWG 6.
2.5.7 Heat Load
Table 13 Heat Load
Supplier Component Heat Load (BTUs per Hour)
BIC 340
AIC 340
RBS 320
RF Shelf TBD
RadioFrame Networks
PDU 10
iSC-3 140
EAS 170
Non-RFN
CSU 140
TOTAL
2.5.8 RF Performance
The MC-Series system will meet the emissions mask requirements per FCC Part 90,
section 90.691.