2.1 MC-Series High Power System Configuration
The MC-Series High Power system can be configured to have 1, 2 or 3 sectors. The
single-sector configuration can have up to 12 BRs. In multi-sector configurations, up to 12
BRs may be assigned per sector, providing a maximum capacity of 36 BRs in a 3-sector
configuration. As shipped, the MC-Series system is configured for 3 sectors.
Configurations are summarized in Table 2.
Table 2 Sectorization and Maximum BR Allocation
Max RF Carrier per Sector Configuration
Sector 1 Sector 2 Sector 3
One Sector Site
12 NA NA
Two-Sector Site
12 12 NA
Three Sector Site
12 12 12
The MC-Series High Power system includes the following RadioFrame Networks
hardware:
Power Distribution Unit (PDU) distributes DC power and provides overcurrent
protection to each component in the MC-Series system cabinet.
Airlink/BTS Interface Chassis (ABIC) performs the digital receive and transmit
function for each RadioBlade
®
transceiver, provides the common timing source for
the RBS and is the interface to the iSC and routes Ethernet traffic for up to three
sectors.
iDEN multi-channel RadioBlade (MCRB) transceivers insert into slots in the RBS;
each MCRB corresponds to up to six iDEN carriers in the 800 or 900 MHz band.
Diversity RadioBlade Shelf (RBS) supports up to 36 BR, utilizing 6 Multi-Channel
RadioBlade transceivers, with an additional 6 MCRB for receive diversity.
Rx Filter Shelf is equipped with two identical Rx paths per sector for receive
diversity.
Tx Filter Shelf is a quadplexer for the Tx signal from both the 800 and 900 MHz
multi-channel power amplifiers (MCPAs) and the Rx signal from both the 800 and
900 MHz bands.
Tx Sampling Ports, or sniffer ports, on the front of the Tx Filter Shelf allow the Tx
signals to be monitored without affecting normal operation.
DC-DC Converter Bank supply +28 VDC to the six MCPAs.
The MC-Series system includes the following non-RadioFrame Networks hardware:
iSC-3s: two integrated Site Controllers (iSC 3s) for redundancy
Caution!
Tx Sampling Ports may exceed +30 dBm peak power. This is composite output
power.